Datasheet | May 2, 2012

Liquicap T FMI21 Datasheet

Application
The Liquicap T sensor is used in conductive liquids (greater than 30 μS/cm) for continuous level measurement and is preconfigured from factory 0 % to 100 % to probe length ordered.

In conductive liquids greater than 30 μS/cm, the measurement is independent of the dc-value (dielectric constant) of the liquid. It can also be used in Ex areas, Zone 2.

The Liquicap T is particularly suited to the following applications:

  • Small measuring ranges (greater than 6" / 150 mm)
  • Cistern measurements
  • Aggressive liquids (many acids and alkalis)
  • Independent of the tank material (plastic, stainless steel or concrete) or the tank shape

Used in conjunction with the Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap T is an ideal solution for inventorying material and optimizing logistics (inventory control).

Your benefits

  • Safe function regardless of tank geometry thanks to probe design
  • No calibration necessary (preconfigured from factory 0 % to 100 % to probe length ordered)
  • High quality, non-corrosive materials (carbon fibre, stainless steel) for use in aggressive liquids and liquids which present a hazard to water (WHG-approved (German Water Resources Law))
  • No moving parts in tank - long operating life - dependable function without wear
  • Cost-effective solution for continuous measurement of levels in conductive liquids
  • Optimized storage by simply shortening the probe rods on site (probe shortening kit)
access the Datasheet!

Get unlimited access to:

Trend and Thought Leadership Articles
Case Studies & White Papers
Extensive Product Database
Members-Only Premium Content
Welcome Back! Please Log In to Continue. X

Enter your credentials below to log in. Not yet a member of Power Online? Subscribe today.

Subscribe to Power Online X

Please enter your email address and create a password to access the full content, Or log in to your account to continue.

or

Subscribe to Power Online