Flange Sealing

Source: Plastocor Inc.
Air inleakage into steam turbines has far-reaching consequences on plant efficiency and equipment life
Air inleakage into steam turbines has far-reaching consequences on plant efficiency and equipment life. An increase in condenser back pressure can throttle unit efficiency and, in extreme cases, cause low pressure turbine blade flutter. High levels of dissolved O2 elevate corrosion in the feed water heater train, boiler, and steam generator systems. Corrosion contributes to poor heat transfer and threatens system integrity. High levels of dissolved CO2 , balanced with ammonia to control pH, can increase ionic concentrations in the condensing steam. Turbine disk cracking, and other failure mechanisms result. Hydrazene becomes an inefficient oxygen scavenger at lower temperatures which makes air inleakage from the condenser particularly troublesome. Over time, the gasket between the waterbox and tubesheet can start to breakdown due to embrittlement. Hydrodynamic stresses from waterbox loading and possible startup water hammer further aggravate gasket integrity. Differential thermal stresses resulting from steam dumps, black trips, and the like compound the problem. Air inleakage around the gasket, through the bolt holes, and into the condenser shell is the result. A variety of leak sealing methods have been employed resulting in various degrees of success. Leak paths can be elusive with new ones forming. Improperly applied sealing materials can delaminate. Often additional sealing materials are applied over old repairs which can result in an ineffective buildup of various paints, anti-sweat coatings, caulks, and other compounds around the external condenser flange. Plastocor Inc. has developed a methodology whereby these old materials are completely removed and a new, sealing system installed, whereby air inleakage is completely eliminated from the waterbox-to-tubesheet flange area. In addition, these methods can be applied to most any other areas in the system where air intrudes. For the external joint, these methods can be employed while the unit is either on-line or off. The sealing system can be installed as the previous materials are removed so severe leaks can be resealed as they are uncovered. On-line applications should be done in conjunction with leak detection surveillance. The system is equally effective when applied on the inside of the waterbox to stop cooling water inleakage or air inleakage in situations where the waterboxes are not completely flooded.

Plastocor Inc., 100 Research Road, Hingham, MA 02043. Tel: 781-749-5050; Fax: 781-749-5075.